CE承認済みの病院用ポータブル医療AED心臓除細動器(緊急機器の代替パターン)

最小注文数量:1セット
パッケージの詳細:Carton Size:425*415*550mm:,1set/Carton
支払条件:T/T 50% デポジット、50% 残高コピー B/L
連絡先

  • 製品導入

原産地:

中国

認定:

ISO、CE

DePrecautions
1. To ensure safety during operation, patients remove dentures.
2. Conductive materials must not be connected, and evenly spread to avoid local skin burns.
3. Master the handle pressure.
4. Keep the electrode plates clean and spaced 10cm apart.
5. In order to be able to accurately time, the record should be based on a clock.
6. Avoid ulcers or wounds.
7. Avoid the built-in pacemaker.
8. Incorrect charging must be discharged on the defibrillator.
9. Try to avoid high oxygen environment.
10. When defibrillating during CPR, defibrillation should be discharged at the end of the patient's expiration to reduce the transthoracic electrical impedance.scription:

用途
Suitable for rescue of cardiac arrest and ventricular fibrillation

仕様:

1.▲The external defibrillation monitor is equipped with an 8.4-inch color TFT display with a resolution of 800X600, and the interface can display up to 4 monitoring parameter waveforms

2. The display mode has a high-contrast display interface, and an external monitor can be connected via VGA.

3. The biphasic exponential truncation (BTE) waveform is adopted, and the waveform parameters can be automatically compensated according to the patient's impedance;

4. Support electrode types: external defibrillation electrode plate, multi-function electrode sheet and internal defibrillation electrode plate, of which the external electrode plate is an adult/child multifunctional integrated type;

5. The external electrode plate provided by the external defibrillation monitor has the functions of supporting charging, discharging, energy selection and other operation functions and has a charging completion indicator

6.▲In external manual defibrillation and synchronized defibrillation, the range of defibrillation energy selection is 25, the minimum is 1J, the maximum is 360J;

7.▲Patient impedance range: external defibrillation: 20~250 ohms; internal defibrillation: 15-250 ohms;

8. The external defibrillation monitor supports AED defibrillation function as standard. The shock energy is configurable from 100J to 360J. The configuration complies with the AHA2010 first aid guide. It can shock the heart rate VF, VT.

9. The external defibrillation monitor supports CPR cardiopulmonary resuscitation rescue prompts, and can guide the operator to perform CPR operations, and the process meets the requirements of the CPR guidelines in the AHA2010 first aid guidelines

10. The external defibrillation monitor supports the internal defibrillation function. The internal defibrillation shock board is optional. When the internal defibrillation is manually defibrillated, the range of defibrillation energy selection is 14 kinds, the minimum is 1J, the maximum is 50J

11. In the case of battery power supply, the defibrillation monitor is charged to 200J for less than 5s, and charged to 360J for less than 8s;

12. When the external defibrillation monitor is turned off and connected to AC power, it will automatically detect according to the set time, including routine inspections and high-energy inspections

13. The pacing mode has fixed pacing and on-demand pacing

14. Pacing waveform: unidirectional square wave pulse, pulse width is 20ms±1.5ms

15. Optional upgrade to achieve 12-lead ECG, SPO2, 2-channel body temperature, NIBP, 2-channel IBP, side-flow end-tidal CO2

16.▲The types of arrhythmia that can be monitored are greater than or equal to 26;

17.▲120-hour trend chart and trend table, 200 parameter alarm events, 2000 sets of blood pressure data, 480min recording storage, 120-hour holographic waveform

18. The external defibrillation monitor provides two alarm functions: technical alarm and physiological alarm, with three alarm methods: sound alarm, light alarm, and text description

19.▲The external defibrillation monitor can be equipped with a maximum of 2 lithium-ion batteries, of which one can support at least 360J defibrillation 210 times, and a single ECG test is greater than or equal to 6 hours

20. There is a multi-segment light-emitting diode (LED) battery indicator device on the battery body, which can be used to quickly evaluate the battery capacity;

21. The external defibrillation monitor is equipped with an 80mm recorder, which can be set to automatically print charging events, discharging events, automatic detection reports, marking events and 12-lead reports

22. Real-time recording time is 3 seconds, 5 seconds, 8 seconds, 16 seconds, 32 seconds, continuous to choose from

23. The IP protection level of the external defibrillation monitor meets the IP44 level requirements